Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification within vivodosimetry
نویسندگان
چکیده
منابع مشابه
Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process
Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملPatient Specific IMRT Pre-Treatment Verification Using A Commercial Portal Dosimetry Software
Introduction: Electronic portal imaging devices (EPIDs) are extensively used for dosimetric information of pre-treatment field verification and in-vivo dosimetry for Intensity Modulated Radiotherapy (IMRT). In the present work, we have implemented the newly developed portal dosimetry software using independent dose prediction algorithm EPIDose and evaluated this new tool for the pretreatment IM...
متن کاملSampling considerations for intensity modulated radiotherapy verification using electronic portal imaging.
A model has been developed to describe the sampling process that occurs when intensity modulated radiotherapy treatments (delivered with a multileaf collimator) are imaged with an electronic portal imaging device that acquires a set of frames with a finite dead-time between them. The effects of the imaging duty cycle and frame rate on the accuracy of dosimetric verification have been studied. A...
متن کاملClinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
The aim of this study was to demonstrate how dosimetry with an amorphous silicon electronic portal imaging device (a-Si EPID) replaced film and ionization chamber measurements for routine pre-treatment dosimetry in our clinic. Furthermore, we described how EPID dosimetry was used to solve a clinical problem. IMRT prostate plans were delivered to a homogeneous slab phantom. EPID transit images w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The British Journal of Radiology
سال: 2010
ISSN: 0007-1285,1748-880X
DOI: 10.1259/bjr/31573847