Power system observability with minimum phasor measurement units placement

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power system observability with minimum phasor measurement units placement

This paper presents optimal phasor measurement units (PMUs) placement algorithms for power system observability. The optimal placement problem (OPP) is formulated such that minimizing the number of PMU installations for full network observability. Three approaches, in this paper, are introduced aiming at reducing the computational burden in Optimal Placement problems. Depth First Search, Simula...

متن کامل

Binary Jaya Algorithm Based Optimal Placement of Phasor Measurement Units for Power System Observability

Owing to the technological advancement in communication areas, presently, the security and the reliability of operating power system is very much possible on real-time platform. Phasor measurement units (PMUs) are based on these advance communication technology and are one of the most important equipment for electric utility, now a days, helpful in maintaining a healthy operating power system. ...

متن کامل

Optimal Phasor Measurement Unit Placement in the Observability of Power System by using Spanning Tree Algorithm

Phasor Measurement Unit’s (PMU) are power system devices which provide real time synchronized phasor measurements. Synchronization is achieved by same-time sampling of voltage and current waveforms by means of timing signals from the Global Positioning System Satellite (GPS). Synchronized phasor measurements make higher the standards of power system monitoring, control, and protection. Since PM...

متن کامل

Optimal Placement of Phasor Measurement Unit for Better Power System Observability

Secure and reliable opertation of the grid requires real time monitoring and control of entire power system. Phasor measurement units (PMU) are being deployed for real time monitoring and analysis of power system. The most important factor to be considered in placement problem is observability of power system with minimum number of PMUs. This paper proposed an Integer Linear Programming (ILP) b...

متن کامل

Optimal Placement of Phasor Measurement Units for Improving Power System State Estimation Accuracy: A Heuristic Approach

This paper describes a heuristic approach for optimal placement of phasor measurement units (PMUs) in power system for improving state estimation accuracy. PMUs are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are installed. Due to cost consideration of PMU placement, power grid utilities are interested in the knowledg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Engineering, Science and Technology

سال: 2018

ISSN: 2141-2839,2141-2820

DOI: 10.4314/ijest.v5i3.1