Recent results on the Power Quality of Italian 2x25 kV 50 Hz railways
The recordings of the pantograph voltage and current waveforms across Italian and French high speed railway lines (both Autotransformer 2x25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various rolling stock operating conditions. These indexes, that define the electrical interface ...
متن کاملA comprehensive control strategy of railway power quality compensator for AC traction power supply systems
The development of electrical railway systems leads to critical power quality problems in the power grid. This paper discusses a kind of half-bridge-based railway power quality compensator system (HBRPQC) that can compensate negative sequence currents, harmonics, and reactive power simultaneously. In order to keep the HBRPQC performance efficient for the different kinds of transformers used in ...
متن کاملProtection setting in 2x25 kV 50 Hz railway traction systems by digital simulation
In this paper, after a short description of the problems related to the detection of short circuits in 2x25 kV 50 Hz traction systems, a methodology for the choice of the operating area of the relay for protections based on the comparison between a measured line impedance and a fixed minimum impedance is presented. The proposed methodology has been realized through the development of a procedur...
متن کاملMeasurements on 25 kV Traction Power Supply Systems
At the moment 25 kV traction power supply systems are being introduced in the Netherlands. Currently in the Netherlands a 1500 V DC system is used, however due to increasing energy demands this system is no longer sufficient. For the high-speed lines and heavy freight lines, which are under construction, the 2x25 kV AC system has been chosen. Introduction of this new technology leads to differe...
متن کاملHarmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...