Power loss estimation due to difference transformer tap changer position at interface
نویسندگان
چکیده
منابع مشابه
Effect of Solid-State on Load Distribution Transformer Tap-Changer on Power Quality Enhancement
Recently electronic tap-changer has received more attention due to its quick response, better performance and simpler maintenance compared to the mechanical tap-changer. This paper presents the capability of the distribution transformer equipped with an electronic tap-changer for improving power quality. At this end, the analytical computation for determining the compensating limit of electroni...
متن کاملInnovative Transformer Load Tap Changer Control Using Ethernet-Based Communications
This paper describes the design of a load tap changer (LTC) control for up to four parallel transformers using a modified circulating current approach. The LTC control discussed in this paper was implemented using programmable logic, math functions, and IEC 61850 communications over fiber-optic Ethernet. One LTC control is associated with each transformer. The current angle from each LTC contro...
متن کاملSolid - State On Load Tap - Changer for Transformer Using Microcontroller
The on-load tap changing (OLTC) regulators have been widely used since the introduction of electrical energy. They ensure a good regulation of the output voltage in presence of large variations of the input voltage with typical response time from several mili-seconds to several seconds. Earlier mechanical type of on load tap changers were into practice. But they had considerable limitations and...
متن کاملThermal model of oil power transformers with a tap changer
The paper presents a new method for on-line temperature calculation taking into account change in the tap changer position. The method introduces accurate calculation of the losses, depending on the current, average temperature of the winding, and tap changer position (it affects both Joules (DC) losses and stray losses). The thermal model itself is the common three-body model (for a transforme...
متن کاملA Sensitive ANN Based Differential Relay for Transformer Protection with Security against CT Saturation and Tap Changer Operation
This paper presents an artificial neural network (ANN) based scheme for fault identification in power transformer protection. The proposed scheme is featured by the application of ANN to identifying system patterns, the unique choice of harmonics of positive sequence differential currents as ANN inputs, the effective handling of current transformer (CT) saturation with an ANN based approach, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Fundamental and Applied Sciences
سال: 2018
ISSN: 1112-9867
DOI: 10.4314/jfas.v9i3s.53