Power Factor Improvement Using a Three Phase Shunt Active Power Filter
نویسندگان
چکیده
منابع مشابه
Shunt Active Filter for Power Quality Improvement
This paper describes the development of a low cost shunt active power filter with digital control, which allows dynamic power factor correction and both harmonics and zero-sequence current compensation. The active filter controller is based on the instantaneous power theory (p-q theory) and was implemented using a standard 16 bits microcontroller. The p-q theory is introduced followed by the pr...
متن کاملEfficient Hybrid Shunt Active Power Filter for Improvement of Power Factor and Harmonic Suppression using MATLAB
Power quality management is the main problem that the industry is facing today. This is mainly affected by the generation of harmonics. The growing use of electronic equipment produces a large amount of harmonics in distribution systems because of non-sinusoidal currents consumed by non-linear loads. As we know for the better quality of power, the voltage and current waveforms should be sinusoi...
متن کاملModelling of Three-phase Shunt Hybrid Active Power Filter
The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...
متن کاملPower Quality Improvement Using Fuzzy Controlled Shunt Active Filter
This paper proposes a new control method of three phase active power filterfor reducing the source current harmonics for nonlinear loads. The control strategy includes the dq transformations and hysteresis technique for current injection. Renewable energy source (solar energy) is used as a backup device for converter. Dc voltage deviations due to harmonic injections are tracked by using proport...
متن کاملSingle-Phase Shunt Active Power Filter Using Indirect Control Method
A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Conference on Aerospace Sciences and Aviation Technology
سال: 2015
ISSN: 2636-364X