Power Factor Correction Using Magnetic Energy Recovery Current Switches
نویسندگان
چکیده
منابع مشابه
Power Factor Correction Using Fuzzy Logic Control
Harmonic pollution and low power factor in power systems caused by power converters have been a great concern. To overcome these problems several converter topologies and control schemes have been proposed in recent years. This paper is proposed to study the control techniques for such converters to improve the Power Factor (PF) and reduce total harmonic distortion (THD) in the input current wi...
متن کاملReactive current control through SVC for load power factor correction
This paper discusses a new technique for controlling SVCs (Fixed Capacitor–Thyristor Controlled Reactor) in power systems with the aim of canceling the reactive current component of the load. A complete model of the SVC with its control circuit is set up and simulated in the EMTDC program. The generated harmonics from the proposed SVC controller are considered to design simple tuned filters to ...
متن کاملPower factor correction circuit for low-cost electronic ballast using current-source type
Introduction. With the adoption of standards such as IEC555-2, there is a need to develop electronic ballasts for fluorescent lamps which can perform line current harmonic reduction and high input power factor correction (PFC). Among various filtering techniques, the active power factor corrector with a tioost converter has, been proven to be effective [l 31. The boost-type PFC circuit is one o...
متن کاملDesign and Implementation of Power Factor Correction (pfc) Converter with Average Current Mode Control Using Dsp
This paper presents a digital controlling method for power factor correction converter with boost structure, by applying average current controlling operation at a fixed frequency, to be used at 90-265 Vrms line voltage, based on being applied on DSP. This method which is based designing in analogue domain and converting the resulting model in to digital domain will be discussed in this paper. ...
متن کاملModified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Industry Applications
سال: 2005
ISSN: 0913-6339,1348-8163
DOI: 10.1541/ieejias.125.372