Power Delivered to Mechanical Systems by Random Vibrations
نویسندگان
چکیده
منابع مشابه
Suppression of friction by mechanical vibrations.
Mechanical vibrations are known to affect frictional sliding and the associated stick-slip patterns causing sometimes a drastic reduction of the friction force. This issue is relevant for applications in nanotribology and to understand earthquake triggering by small dynamic perturbations. We study the dynamics of repulsive particles confined between a horizontally driven top plate and a vertica...
متن کاملResearch on Study Mechanical Vibrations with Data Acquisition Systems
The paper presents a new study method of mechanic vibrations with the help of the data acquisition systems. The study of vibrations with the help of data acquisition systems allows the solving of some engineering problems connected to the measurement of some parameters which are difficult to measure having in view the improvement of the technical performances of the industrial equipment or devi...
متن کاملVisual Sensor with Resolution Enhancement by Mechanical Vibrations
The resolution limit of visual sensors due to nite pixel spacing can be overcome by applying continuous low-amplitude vibrations to the image|or taking advantage of existing vibrations in the environment, for instance in a mobile robotics application. Thereby, spatial intensity gradients turn into temporal intensity uctuations which can be detected and processed by every pixel independently fro...
متن کاملOptimization of Piezoelectric Electrical Generators Powered by Random Vibrations
This paper compares the performances of a vibrationpowered electrical generators using PZT piezoelectric ceramic associated to two different power conditioning circuits. A new approach of the piezoelectric power conversion based on a nonlinear voltage processing is presented and implemented with a particular power conditioning circuit topology. Theoretical predictions and experimental results s...
متن کاملInaccuracy of tidal volume delivered by home mechanical ventilators.
Ideally, the inspired (tidal) volume (V(T)) provided by a volume-controlled ventilation device should not change when the pressure imposed on the ventilator varies. A bench study evaluation of V(T) versus pressure was performed on 10 commercially available devices. The difference between the desired V(T) and the observed V(T) reached 100 mL for some devices when inspiratory resistance was at it...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Shock and Vibration
سال: 2009
ISSN: 1070-9622,1875-9203
DOI: 10.1155/2009/457216