Potentiometric titration and conformation of synthetic and natural polyelectrolytes

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric titration and conformation of synthetic and natural polyelectrolytes.

From the analysis of the potentiometric titration data of polyelectrolytes, we can obtain the electrostatic free energy of the macromolecules. Therefore, potentiometric titration is a useful experimental procedure to study the conformation and conformational change of macromolecules. A few examples of the application of potentiometric titration to the studies on polypeptides, protein and DNA ar...

متن کامل

Potentiometric titration and conformational change in pepsinogen.

Potentiometric titrations of pepsinogen as functions of ionic strength and temperature were studied. It was found that the ionic strength has a minor effect on the titration behavior of the protein. The maximum values of the buffering capacity in the pH range of 6.0 to 9.0 were found at pH values corresponding to those at which a conformational change of the protein occurs as determined by opti...

متن کامل

ARM - Based Automatic Potentiometric Titration System

Accurate measurement and analysis are very important tasks for many applications ranging from industrial operations, analytical laboratories to biological processes. In modern analytical chemistry, automatic titrators have more prominence than manual interpretations. Various instruments have been developed and proposed in the past to carry out potentiometric titrations. Also there are suppliers...

متن کامل

postnatal studies of bats (pipistrellus kuhlii and miniopterus schreibersii) & histomorphology and histochemistry studies of organs and diseases of (neurergus microspilotus and n. kaiseri)

1. to determine whether difference in birth body mass influenced growth performance in pipistrellus kuhlii we studied a total of 12 captive-born neonates. bats were assigned to two body mass groups: light birth body mass (lbw: 0.89 ± 0.05, n=8) and heavy birth body mass (hbw: 1.35 ± 0.08, n=4). heavier body mass at birth was associated with rapid postnatal growth (body mass and forearm length) ...

existence and approximate $l^{p}$ and continuous solution of nonlinear integral equations of the hammerstein and volterra types

بسیاری از پدیده ها در جهان ما اساساً غیرخطی هستند، و توسط معادلات غیرخطی ‎‏بیان شد‎‎‏ه اند. از آنجا که ظهور کامپیوترهای رقمی با عملکرد بالا، حل مسایل خطی را آسان تر می کند. با این حال، به طور کلی به دست آوردن جوابهای دقیق از مسایل غیرخطی دشوار است. روش عددی، به طور کلی محاسبه پیچیده مسایل غیرخطی را اداره می کند. با این حال، دادن نقاط به یک منحنی و به دست آوردن منحنی کامل که اغلب پرهزینه و ...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pure and Applied Chemistry

سال: 1971

ISSN: 1365-3075,0033-4545

DOI: 10.1351/pac197126030519