Potentiometric Sensors for Iodide and Bromide Based on Pt(II)-Porphyrin
نویسندگان
چکیده
منابع مشابه
Urinary iodine assays and ionophore based potentiometric iodide sensors.
Urinary Iodine has been widely regarded as a biochemical marker for control of iodine deficiency disorders. Based on the Sandell-Kolthoff reaction, most colorimetric assay methods for urinary iodine (UI) determination that have been developed require pretreatment of urine sample. The non-Sandell-Kolthoff methods for UI assay provide alternative approaches for UI assay requiring only simple pret...
متن کاملManganese(III) Porphyrin-based Potentiometric Sensors for Diclofenac Assay in Pharmaceutical Preparations
Two manganese(III) porphyrins: manganese(III) tetraphenylporphyrin chloride and manganese(III)-tetrakis(3-hydroxyphenyl)porphyrin chloride were tested as ionophores for the construction of new diclofenac-selective electrodes. The electroactive material was incorporated either in PVC or a sol-gel matrix. The effect of different plasticizers and additives (anionic and cationic) on the potentiomet...
متن کاملModern Directions for Potentiometric Sensors.
This paper gives an overview of the newest developments of polymeric membrane ion-selective electrodes. A short essence of the underlying theory is given, emphasizing how the electromotive force may be used to assess binding constants of the ionophore, and how the selectivity and detection limit are related to the underlying membrane processes. The recent developments in lowering the detection ...
متن کاملPotentiometric miniaturized pH sensors based on polypyrrole films
Submitted by Olivier Segut on Fri, 11/07/2014 16:35 Titre Potentiometric miniaturized pH sensors based on polypyrrole films Type de publication Article de revue Auteur Lakard, Boris [1], Segut, Olivier [2], Lakard, Sophie [3], Herlem, Guillaume [4], Gharbi, Tijani [5] Editeur Elsevier Type Article scientifique dans une revue à comité de lecture Année 2007 Langue Anglais Date Jan-03-2007 Numéro ...
متن کاملNovel ibuprofen potentiometric membrane sensors based on tetraphenylporphyrinato indium(III).
Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(II) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2018
ISSN: 1424-8220
DOI: 10.3390/s18072297