Potentiometric Sensors Based on Carbon Paste Electrode
نویسندگان
چکیده
منابع مشابه
Clomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors
Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...
متن کاملPotentiometric carbon paste sensors for lead(II) based on dithiodibenzoic and mercaptobenzoic acids.
Dithiodibenzoic (DTB) acid and mercaptobenzoic (MB) acid were studied to characterize their abilities as modifier agents for lead(II) sensors. For both sensors, the best results were obtained with modified carbon paste electrodes with 24.1% of ligand. The pH influence on the potentiometric response was studied. The selectivity coefficients for both modified electrodes were tabulated. A potentio...
متن کاملSelective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)
Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...
متن کاملA Novel Carbon Paste Electrode for Potentiometric Determination of Vanadyl Ion
Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...
متن کاملCOBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Denki Kagaku oyobi Kogyo Butsuri Kagaku
سال: 1992
ISSN: 0366-9297,2434-2556
DOI: 10.5796/electrochemistry.60.1146