Potentiometric Membrane Sensors for Determination of Memantine Hydrochloride and Pramipexole Dihydrochloride Monohydrate

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

PVC Membrane Sensors for Potentiometric Determination of Acebutolol

The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC) withtetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge catio...

متن کامل

Clomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors

Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...

متن کامل

Polymeric Membrane Sensor for Potentiometric Determination of Tin(II) Ions

Tin(II)-ion-selective electrode consisting of dibenzo-18-crown-6 (DB18C6) as an ionophore inPVC matrix was developed. The influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. The electrodeshowed a near Nernstian response for Sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Portugaliae Electrochimica Acta

سال: 2012

ISSN: 1647-1571

DOI: 10.4152/pea.201201031