Potentiometric ion-selective sensors based on UV-ozone irradiated laser-induced graphene electrode
نویسندگان
چکیده
Disposable devices for sensing biomarkers like Na+ ion in sweat was developed using UV-Ozone irradiated laser-induced graphene (LIG) based electrodes. Solid-state ion-selective electrodes (ISEs) sensitive to ions were fabricated by a two-step drop-coating process of polyvinyl chloride solution containing plasticizer, ionophore and ion-exchanger on LIG electrode. Hydrophobic hydrophilic transition induced treatment reduced the contact angle, resulting better permeation membrane into ozonized film. Raman spectroscopy IR absorption studies indicate physisorption ozone LIG. Performance (O-LIG) much than pristine screen-printed carbon Sensitivity 60.2 ± 0.9 mV/ decade lower limit detection 1 × 10?6 M achieved O-LIG ISEs. Response time around min.
منابع مشابه
Polymer membrane-based ion-, gas- and bio-selective potentiometric sensors.
Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological...
متن کاملLanthanum(III) Ion Selective Electrode Based on a New Ionophore
A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملChromium (III) ion selective electrode based on di(benzylamino)glyoxime
A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملlanthanum(iii) ion selective electrode based on a new ionophore
a pvc membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(iii) ion was prepared. this electrode revealedsuch a good selectivity toward la3+ ion over a wide variety of other metal ions. some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrochimica Acta
سال: 2021
ISSN: ['1873-3859', '0013-4686']
DOI: https://doi.org/10.1016/j.electacta.2021.138341