Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potentiometric Flow Injection Analysis of Bromhexine Hydrochloride and its Pharmaceutical Preparation Using Conventional and Coated Wire Ion-Selective Electrodes

Bromhexine hydrochloride ion-selective electrodes (conventional type) based on bromhexinium tetraphenyl borate (I) and bromhexinium-phosphotungstate (II) were prepared. The electrodes exhibited mean slopes of calibration graphs of 59.4 mV and 59.8 mV per decade of bromhexine concentration at 25 C for electrode (I) and (II), respectively. Both electrodes could be used within the concentration ra...

متن کامل

New conventional coated-wire ion-selective electrodes for flow-injection potentiometric determination of chlordiazepoxide.

New chlordiazepoxide hydrochloride (Ch-Cl) ion-selective electrodes (conventional type) based on ion associates, chlordiazepoxidium-phosphomolybdate (I) and chlordiazepoxidium-phosphotungstate (II), were prepared. The electrodes exhibited mean slopes of calibration graphs of 59.4 mV and 60.8 mV per decade of (Ch-Cl) concentration at 25 degrees C for electrodes (I) and (II), respectively. Both e...

متن کامل

Ion-selective electrodes for potentiometric determination of ranitidine hydrochloride, applying batch and flow injection analysis techniques.

New ranitidine hydrochloride (RaCl)-selective electrodes of the conventional polymer membrane type are described. They are based on incorporation of ranitidine-tetraphenylborate (Ra-TPB) ion-pair or ranitidine-phosphotungstate (RaPT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphthalate (DOP) or dibutylphthalate (DBP). The electrodes are fully characterized in...

متن کامل

Potentiometric determination of Benzydamine hydrochloride using PVC membrane and coated wire sensors in pure form, pharmaceutical compounds and biological fluids

The construction and electrochemical response characteristics of PVC membrane and coated wire sensors for the determination of Benzydamine hydrochloride (Benz) are described. PVC membrane sensors, include sensors 1, 2 and 3, and coatedwire sensors include sensors 4, 5 and 6. Sensors 1 and 4 based on benzydamine phosphotungstate (Benz-PTA) as ion-pair, sensors 2 and 5 based on benzydamine phosph...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientia Pharmaceutica

سال: 2006

ISSN: 0036-8709

DOI: 10.3797/scipharm.2006.74.121