Potentiometric determination of Tantalum content in ores using an ion selective membrane electrode
نویسندگان
چکیده
منابع مشابه
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملKinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.
We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملPotentiometric determination of silver(I) by selective membrane electrode based on derivative of porphyrin.
The performance of silver metal complexes with meso-tetraphenylporphyrin ([H2T(4-CH3)]PP) as ionophores for ion-selective electrodes was studied. The electrode exhibited linear response with Nernstian slope of 59.2 +/- 1.0 mV per decade within the concentration range of 1.0 x 10(-7)-1.0 x 10(-1) M silver ions. The limit of detection as determined from the intersection of the extrapolated linear...
متن کاملDetermination of potassium ion concentration in serum using a highly selective liquid-membrane electrode.
The potassium-selective glass membranes like KAS,,_, and NAS,,_, are approx. IO times more sensitive to K+ than to Na +lp3. Since the concentration ratio of Na+/K+ in blood serum is around 35-40 and since there is at best a K+ over Naf selectivity in glass electrodes of IO, a separate measurement of the Na+ concentration is needed to correct the reading of the K+ sensor 4. Because of the depend...