Potentiometric detection in ion chromatography using multi-ionophore membrane electrodes

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Ion-Selective Electrodes With Ionophore-Doped Sensing Membranes

At the time of this writing, more than 20 000 publications related to ion-selective electrodes (ISEs)1–7 have been published, with approximately two new ones per day in recent years. Figure 1 shows, for the period between 1970 and 2009, the continuing increase in the number of publications that could be readily recognized as reporting on the preparation or use of ionophore-based ISEs. Clearly, ...

متن کامل

Potentiometric Based Membrane Sensor for Zinc Ion

A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08  10-5-1.00  10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...

متن کامل

Ionophore-based ion optodes without a reference ion: electrogenerated chemiluminescence for potentiometric sensors.

We report here on an electrogenerated chemiluminescence (ECL) readout for potentiometric ion-sensors, thereby offering an optical sensor output without the need for a reference ion (typically the hydrogen ion) that inconveniences ionophore based optical sensor principles. The compartment for ECL generation is physically separated from the sample by a bridge, and no current flows through the sam...

متن کامل

Potentiometric sensing of aqueous phosphate by competition assays using ion-exchanger doped-polymeric membrane electrodes as transducers.

Using Zn(2+)-BPMP or Cu(2+)-BPMP as a receptor and o-mercaptophenol as an indicator, potentiometric sensing of aqueous phosphate by competition assays was achieved. With attractive features of portability, low cost and resistance to interference from turbidity and color, this sensor was successfully used for phosphate detection in biological and water samples.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Chromatography A

سال: 1993

ISSN: 0021-9673

DOI: 10.1016/0021-9673(93)83313-h