Potentiometric coated wire electrode for salicylate based on zinc(II) acetylacetonate
نویسندگان
چکیده
منابع مشابه
Potentiometric Coated Wire Electrode for Salicylate based on Zinc(II) Acetylacetonate
Um eletrodo na forma de fio modificado com acetilacetonato de zinco(II) como agente ionóforo, mostrou um comportamento de íon-seletivo exibindo uma resposta linear Nernstiana com uma inclinação igual a –59.6 ± 1.0 mV/década para uma ampla faixa de concentração (1.0 × 10-1.0 × 10 mol L). O eletrodo apresentou um limite de detecção igual a 5.0 × 10 mol L e tempo de resposta entre 5 a 10 s para at...
متن کاملPotentiometric membrane electrode for salicylate based on an organotin complex with a salicylal Schiff base of amino acid.
A novel salicylate-selective electrode based on an organotin complex with a salicylal Schiff base of amino acid salicylaldehydeaminoacid-di-n-butyl-Sn(IV) [Sn(IV)-SAADB] as ionophore is described, which exhibits high selectivity for salicylate over many other common anions with an anti-Hofmeister selectivity sequence: Sal- >> PhCOO- > SCN- > Cl04- > I- > NO3- > NO2- > Br- > Cl- > CH3COO-. The e...
متن کاملAl(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore
A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M with Nernstian slope of 19...
متن کاملCoated wire silver-ion selective electrode based on a N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0...
متن کاملSilver(I)-selective coated-wire electrode based on an octahydroxycalix[4]arene derivative.
The performance of octahydroxycalix[4]arene derivative used as a neutral carrier for silver polymeric membrane electrode was studied. The sensor gave a good Nernstian response of 58 +/- 1 mV per decade for silver ion in the activity range 3.3 x 10(-6) to 3.3 x 10(-2) M Ag+. The limit of detection reached 2.1 x 10(-6) M Ag+ and exhibited high selectivity for silver ion against the alkali, alkali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2007
ISSN: 0103-5053
DOI: 10.1590/s0103-50532007000400017