Potentiometric C2H4-Selective Detection on Solid-State Sensors Activated with Bifunctional Catalytic Nanoparticles
نویسندگان
چکیده
This work presents a solid-state ionic-based device to selectively detect C2H4 in car exhaust gases. The sensor consists of 8YSZ as the electrolyte and two electrodes: Fe0.7Cr1.3O3/8YSZ LSM/8YSZ. main aim this is optimize catalytic behavior working electrode reduce cross-sensitivity toward CO H2O. Several catalyst nanoparticles were infiltrated tailor adsorption electrochemical oxidation properties while diminishing conversion other gas components such CO. metal catalysts selected, taking into account both redox properties. Infiltration Ti or Al, followed by second infiltration Ni, enabled selective detection with low H2O moist environment. Further insight potentiometric sensing achieved impedance analysis electrodes activated bifunctional catalysts.
منابع مشابه
Spray-coated all-solid-state potentiometric sensors.
A novel fully spray coating-based method of the preparation of all-solid-state ion-selective electrodes of simplified construction is proposed. This method is an alternative for screen-printed electrodes used sometimes in potentiometric applications. The benefits of the herein-proposed approach include fully automatic sensor preparation and minimized use of chemicals allowing for the production...
متن کاملall solid state graphene based potentiometric sensors formonitoring of mercury ions inwastewater samples
in this work, all-solid-state potentiometric pvc membrane sensor was introduced for fast andsimple monitoring of mercury ions in waste water samples. the all solid sate electrode is made based on aconductive composite of graphite, reduced graphene oxide, epoxy resin on a copper wire. a thin layer pvcmembrane is then coated on the surface of the new conducting transducer. pvc membrane is compose...
متن کاملDetermination of the capacitance of solid-state potentiometric sensors: An electrochemical time-of-flight method.
A dual microelectrode electrochemical time-of-flight technique in which diffusion flux of Ag+, Cl-, or H+ ions electrochemically produced at a generator electrode is measured by recording potential-time transients with Ag, Ag/AgCl, or iridium oxide potentiometric microsensors, respectively, is developed. The generator and microsensor electrodes are typically spaced by 50-100 microm and are inco...
متن کاملPolymer membrane-based ion-, gas- and bio-selective potentiometric sensors.
Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological...
متن کاملImproved potentiometric response of all-solid-state Pb(2+)-selective electrode.
Zero-current ion-flux has a great influence on the characteristics of the ion-selective electrodes. In this work the improvement of analytical performance of all-solid-state Pb(2+)-selective membrane electrodes was demonstrated by adjusting the transmembrane ion flux. The study is focused on the relationship between the conditioning solution and the linear working range of the obtained electrod...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemosensors
سال: 2021
ISSN: ['2227-9040']
DOI: https://doi.org/10.3390/chemosensors9100274