Posture and activity monitoring using a 3-axis accelerometer
نویسندگان
چکیده
منابع مشابه
Posture and Activity Detection Using a Tri-axial Accelerometer
Quantifying activity levels among healthy older adults and patients can provide objective information on sedentary behavior and physical function [1]. In order to accurately quantify activity in the free-living environment, a robust method for classifying posture and activity needs to be established. Therefore, the purpose of this study was to validate the identification of static postures and ...
متن کاملRE<C: Heliostat Orientation Estimation Using a 3-Axis Accelerometer
After testing many different designs, we built a rough orientation control system using a 3-axis accelerometer, able to sense and direct mirror orientation with close to one degree of precision (20 milliradians) for the entire motion range of the mirror. This level of precision is required for orientation tasks such as stowing the mirror in high winds and bringing the light spot close enough to...
متن کاملADL Monitoring System Using FSR Arrays and Optional 3-Axis Accelerometer
This paper deals with Activities of Daily Living (ADL) Monitoring System. The proposed system takes into account deploying in real home. The important issue in deployment is the noninvasiveness. That is, the user should not feel inconvenience. Therefore, our system has been developed by making use of FSR sensors and an optional small bodyactivity sensor. In particular, FSR sensor is a typical n...
متن کاملActivity classification using 3-axis accelerometer and pulse oximeter wearing on wrist for the elderly
In this paper we propose new criteria to classify daily life activities using accelerometer and pulse oximeter. As a result, once the device decides in emergence, it sends a short message to server and then connected to the u-Healthcare center or emergency center and one’s family.
متن کاملTilt Measurement Using a Dual Axis Accelerometer
Rev.0 Circuits from the LabTM circuits from Analog Devices have been designed and built by Analog Devices engineers. Standard engineering practices have been employed in the design and construction of each circuit, and their function and performance have been tested and verified in a lab environment at room temperature. However, you are solely responsible for testing the circuit and determining...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Sensor Science and Technology
سال: 2007
ISSN: 1225-5475
DOI: 10.5369/jsst.2007.16.6.467