Postoperative Achilles Pull-out Strength after Calcaneoplasty for Haglund’s Syndrome

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic Calcaneoplasty for Haglunds Excision Using Two Lateral Portals

Introduction The main objective of this case report is to demonstrate endoscopic calcaneoplasty (ECP) using two lateral portals. Case Report The patient is middle-aged male aged 40 years, with higher basal metabolic index (BMI) and was diagnosed having a Haglund's bump and was on conservative treatment for a period of over 6 months, with minimal relief. We did ECP with the patient in lateral ...

متن کامل

Outcome of calcaneoplasty in insertional achilles tendinopathy.

ABSTRACT BACKGROUND Insertional Achilles tendinopathy may be associated with Haglund's deformity and result in chronic pain. It is usually refractory to conservative management. The aim of this study was to assess the outcome of calcaneoplasty performed in our hospital. METHODS Eight patients were prospectively evaluated pre- and postoperatively using the American Orthopaedic Foot and Ankl...

متن کامل

Calcaneoplasty and reattachment of the Achilles tendon for insertional tendinopathy.

PURPOSE To report the one-year outcome of 44 patients treated with a novel technique of calcaneoplasty and reattachment of the Achilles tendon. METHODS 15 men and 29 women (mean age, 53 years) with insertional tendinopathy of the Achilles tendon underwent calcaneoplasty, retrocalcaneal bursa excision, debridement and reattachment of the Achilles tendon with suture anchors via a lateral approa...

متن کامل

Pull-out strength of screws from polymethylmethacrylate cement.

We aimed to determine the optimal method of inserting a screw into polymethylmethacrylate (PMMA) cement to enhance fixation. We performed six groups of ten axial pull-out tests with two sizes of screw (3.5 and 4.5 mm AO cortical) and three methods of insertion. Screws were placed into 'fluid' PMMA, into 'solid' PMMA by drilling and tapping, or into 'curing' PMMA with quarter-revolution turns ev...

متن کامل

Studies on the pull-out strength of ribbed bars in high-strength concrete

The transfer of forces from reinforcing bars to surrounding concrete in reinforced concrete (RC) is influenced by many parameters. Several efforts were made to understand the influence of bond on global behaviour of RC members. However, the information on bond strength of high strength concrete (HSC) is lacking. An attempt was made to study the influence of various parameters on bond such as ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Foot & Ankle Orthopaedics

سال: 2018

ISSN: 2473-0114,2473-0114

DOI: 10.1177/2473011418s00383