Sudden death in patients with implantable cardioverter defibrillators: the importance of post-shock electromechanical dissociation.
OBJECTIVES The purpose of this study was to determine the mechanisms of sudden death (SD) in patients with ventricular tachyarrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]) treated with an implantable cardioverter defibrillator (ICD). BACKGROUND Despite ICD therapy, some patients with VT/VF still die suddenly. Optimal ICD use requires determination of the mechanisms of t...
متن کاملConstitutively Active Acetylcholine-Dependent Potassium Current Increases Atrial Defibrillation Threshold by Favoring Post-Shock Re-Initiation
Electrical cardioversion (ECV), a mainstay in atrial fibrillation (AF) treatment, is unsuccessful in up to 10-20% of patients. An important aspect of the remodeling process caused by AF is the constitutive activition of the atrium-specific acetylcholine-dependent potassium current (IK,ACh → IK,ACh-c), which is associated with ECV failure. This study investigated the role of IK,ACh-c in ECV fail...
متن کاملImplantable cardioverter defibrillator with and without defibrillation threshold testing.
BACKGROUND Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. This practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test. OBJECTIVES To compare the outcome of ICD recipients who underwent DFT testing and those who did not...
متن کاملSystematic Review of Defibrillation Threshold Testing at De Novo Implantation.
BACKGROUND Recent results from the largest multicenter randomized trial (Shockless IMPLant Evaluation [SIMPLE]) on defibrillation threshold (DFT) testing suggest that while shock testing seems safe, it does not reduce the risk of failed shocks or prolong survival. A contemporary systematic review of DFT versus no-DFT testing at the time of implantable cardioverter-defibrillator implantation was...
متن کاملElevated Defibrillation Threshold: Are Defibrillation Vectors Important?
The evaluation of the defibrillation threshold (DFT) is common after the implantation of implantable cardioverter defibrillator (ICD) devices. The goal of this standard of care is to achieve successful defibrillation of ventricular fibrillation. In patients with elevated defibrillation thresholds, alternative techniques are required to correct the situation. We describe a case in which an uncom...