Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Commercial finite element software generally includes dedicated numerical models for the nonlinear response of concrete under loading. These models usually include a smeared crack analogy to account for the relatively poor tensile strength of concrete, a plasticity algorithm to facilitate concrete crushing in compression regions and a method of specifying the amount, the distribution and the or...

متن کامل

Experimental Study and Modeling of Reinforced Concrete Beams Strengthened by Post-Tensioned External Reinforcing Bars

The utilization of unbounded external reinforcing bars is one of the strengthening methods used after loading stage and before failure. The method has been used in different forms to strengthen members of reinforced concrete structures. To investigate the effect of utilization of post-tensioned reinforcing bars in this method of strengthening, a number of reinforced concrete beams was tested. S...

متن کامل

Flexural Strengthening of Deficient Reinforced Concrete Beams with Post-Tensioned Carbon Composites using Finite Element Modelling

The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...

متن کامل

Unbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires

The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned (UPT) prestressing tendons are used. Despite several studies aimed at furthering our understanding of the response of UPT concrete structures in fire, many aspects of their...

متن کامل

Exploratory experimental investigations on post - tensioned structural glass beams

The mechanical response of post-tensioned glass beams is explored in this paper. This is done through bending experiments on post-tensioned glass beam specimens with either mechanically anchored or adhesively bonded steel tendons by which a beneficial pre-stress is inflicted on the glass beams. In addition, reference beams with identical geometry but without tendons are tested. From the results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil Engineering Journal

سال: 2020

ISSN: 2476-3055,2676-6957

DOI: 10.28991/cej-2020-03091515