PORTABLE VENTILATORS

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Portable ventilators

Mechanical ventilators used in intensive care units are sophisticated devices. The guiding principle in their design is the provision of optimal lung ventilation. They incorporate precise but sizeable pneumatic components intended to utilize piped gases and mains electricity. However, when transporting patients receiving ventilatory support, these devices are rarely suitable because of their si...

متن کامل

Evaluation of 4 new generation portable ventilators.

BACKGROUND Portable ventilators are increasingly utilized in the intra- and inter-hospital transport of patients. We evaluated 4 portable ventilators, Impact EMV, CareFusion LTV 1200, Newport HT70, and Hamilton T1, in terms of triggering, delivered tidal volume (V(T)) accuracy, battery duration, delivered F(IO(2)) accuracy, and gas consumption. METHODS Triggering was tested using a microproce...

متن کامل

Performance of portable ventilators at altitude.

BACKGROUND Aeromedical transport of critically ill patients requires continued, accurate performance of equipment at altitude. Changes in barometric pressure can affect the performance of mechanical ventilators calibrated for operation at sea level. Deploying ventilators that can maintain a consistent tidal volume (VT) delivery at various altitudes is imperative for lung protection when transpo...

متن کامل

Battery life of portable home ventilators: effects of ventilator settings.

BACKGROUND The battery life (BL) of portable home ventilator batteries is reported by manufacturers. The aim of this study was to evaluate the effects of ventilator mode, breathing frequency, PEEP, and leaks on the BL of 5 commercially available portable ventilators. METHODS The effects of the ventilator mode (volume controlled-continuous mandatory ventilation [VC-CMV] vs pressure support ven...

متن کامل

Cement Windows and Ventilators

(Hi) Materials.?The aggregate may be made with 1 part of cement and 3 to 4 of sand, or 1 of cement with 1 of sand and 3 of coal ashes. Iron wire l/8th to 1/16th inch in diameter should be used in every limb, bar or curve of the window. Kerosene oil is good enough for lubricating the mould. Moulds should be emptied, i.e., windows cast, on a layer of sand, spread out and levelled, to prevent stic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 1982

ISSN: 0007-0912

DOI: 10.1093/bja/54.8.900