Porosity Measurement Method by X-Ray Computed Tomography
نویسندگان
چکیده
منابع مشابه
Porosity Measurement Method by X-ray Computed Tomography
Therefore, the new method, called the grey level method, which reflects the phenomenon of image processing and computation of ration between the volume of voids and the total volume of the entire sample, was considered and improved in term of image noise and artifacts. The volumes of 2D CT image as a surface are achieved by means of integrating the surface with operations relating to image hist...
متن کاملEmpirical correlation for porosity deduction from X-ray computed tomography (CT)
For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملX-ray computed tomography.
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictio...
متن کاملempirical correlation for porosity deduction from x-ray computed tomography (ct)
for obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as x-ray computed tomography, ct, seems to be precise and accurate. porosity is deducted from the ct image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. more than one hundred samples with carbonate litho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Key Engineering Materials
سال: 2009
ISSN: 1662-9795
DOI: 10.4028/www.scientific.net/kem.409.402