POOL BOILING HEAT TRANSFER IN A VERTICAL ANNULUS WITH A NARROWER UPSIDE GAP

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pool Boiling Heat Transfer in Water/Amines Solutions

In this investigation, nucleate boiling heat transfer coefficients were experimentally measured during pool boiling of mixtures, consisting of water/monoethanolamine and water/diethanolamine on a horizontal heating rod, under atmospheric pressure. The experiment was carried out below 205 kW.m-2 heat flux, over a wide range of concentrations. These experiments include, measurement of pool boilin...

متن کامل

Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations

Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...

متن کامل

experimental investigation in pool boiling heat transfer of pure/binary mixtures and heat transfer correlations

nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. in this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure ...

متن کامل

Modeling of Upward Subcooled Flow Boiling of Refrigerant-113 in a Vertical Annulus

In this paper, a modified two-fluid model has been adopted to simulate the process of upward vertical subcooled flow boiling of refrigerant R-113 in a vertical annular channel at low pressure. The modified model considers temperature dependent properties and saturation temperature variation and was validated against a number of published low-pressure subcooled boiling experiments. The results s...

متن کامل

Heat transfer in nucleate pool boiling of multicomponent mixtures

Steady state pool boiling heat transfer coefficients have been obtained experimentally for acetone–isopropanol–water and acetone–MEK (methyl ethyl ketone)–water ternary systems. The data show that, for a given heat flux, the heat transfer coefficients of mixtures are lower than those obtained for pure components constituting the mixture. The measured heat transfer coefficients were compared wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Engineering and Technology

سال: 2009

ISSN: 1738-5733

DOI: 10.5516/net.2009.41.10.1285