Polymerization Behavior of Poly(ether ketone) via Friedel–Crafts Acylation Studied by End-Group Analysis with 1H NMR
نویسندگان
چکیده
منابع مشابه
Local deformation behavior of surface porous polyether-ether-ketone.
Surface porous polyether-ether-ketone has the ability to maintain the tensile monotonic and cyclic strength necessary for many load bearing orthopedic applications while providing a surface that facilitates bone ingrowth; however, the relevant deformation behavior of the pore architecture in response to various loading conditions is not yet fully characterized or understood. The focus of this s...
متن کاملDynamic Behavior of Group 13 Elements in Bromocomplexes as Studied by NQR and NMR
NMR, NQR, powder X-ray diffraction, DTA and AC conductivity were measured in RMBr4 (R = Ag, Cu; M = Al, Ga) and RM2Br7 (R = Li, Ag; M = Al, Ga). In RMBr4, the activation energy of Cu diffusion was evaluated fromCu NMR and was in good agreement with that fromBr NQR. In CuAlBr4, the e Qq/h value of Cu NMR and the value of Al NMR changed linearly with decreasing temperature, although the eQq=h val...
متن کاملConformational Study of some novel Methoxy Half-Analogues of Michler’s Ketone by NMR
One series of half-analogues of Michler’s ketone containing one or more terminal methoxysubstituents with variable tertiary amino groups have been used in this study. NMR spectralresults for the parent ketones confirm earlier findings that ortho proton shifts are apparentlyindependent from steric effects in derivatives of Michler’s ketone because the ring current andcarbonyl-induced shifts are ...
متن کاملMean strain effects on cyclic deformation and fatigue behavior of polyether ether ketone (PEEK)
The fatigue behavior of polyether ether ketone (PEEK) thermoplastic was investigated under uniaxial strain-controlled cyclic loading condition with various mean strains (Rε 1⁄4 0, 0.2, and 0.25). The mean stress responses of PEEK from all mean strain fatigue tests were found to be fully-relaxed. As a result, minimum mean strain effect on fatigue behavior of PEEK was observed. Fractography analy...
متن کاملReconstruction of frontal bone using specific implant polyether-ether-ketone.
Defects on the craniofacial complex may result in aesthetic defects, functional damage, and psychologic consequences. Previously, surgeons showed no interest in reconstructing the operated area, but in the treatment of the problem, leaving bone contour is a secondary issue. Nowadays, area reconstruction with post-reestablishment of contour and local shape has become one of the surgeon's priorit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Polymer Journal
سال: 2002
ISSN: 0032-3896,1349-0540
DOI: 10.1295/polymj.34.219