Polymer Membrane Thallium(I)-Selective Electrodes Based on Dibenzo-crown-6 Ethers.
نویسندگان
چکیده
منابع مشابه
Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6
We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...
متن کاملsn (ii) ion- selective membrane electrode based on dibenzo-18-crown-6
we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...
متن کاملDibenzo-18-crown-6
The asymmetric unit of the title compound, C(20)H(24)O(6), contains two mol-ecules that are identical within standard deviations concerning bond lengths and angles as well as their conformations. In the crystal structure, weak C-H⋯O inter-actions help to consolidate the packing.
متن کاملRobust and Ultrasensitive Polymer Membrane-Based Carbonate-Selective Electrodes.
Quantitative analysis of the carbonate species within clinical and environmental samples is highly critical to the advancement of accurate environmental monitoring, disease screening, and personalized medicine. Herein we report the first example of carbonate detection using ultrasensitive ion selective electrodes (ISEs). The low detection limit (LDL) of these electrodes was at least 4 orders of...
متن کاملVoltammetric determination of copper at chemically modified electrodes based on crown ethers.
The feasibility of fabricating copper-sensitive chemically modified electrodes (CMEs) for trace analysis in aqueous and in 40% (v/v) ethanol-water media was investigated. Carbon paste electrodes modified with crown ethers were constructed by mixing the crown ethers into a graphite powder-paraffin oil matrix. The electrodes so formed were able to bind Cu(II) ions chemically and gave better volta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1991
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.7.485