Polyether ether ketone (PEEK) and its 3D printed implants applications in medical field: An overview

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mean strain effects on cyclic deformation and fatigue behavior of polyether ether ketone (PEEK)

The fatigue behavior of polyether ether ketone (PEEK) thermoplastic was investigated under uniaxial strain-controlled cyclic loading condition with various mean strains (Rε 1⁄4 0, 0.2, and 0.25). The mean stress responses of PEEK from all mean strain fatigue tests were found to be fully-relaxed. As a result, minimum mean strain effect on fatigue behavior of PEEK was observed. Fractography analy...

متن کامل

PEEK (Polyether-ether-ketone) Based Cervical Total Disc Arthroplasty: Contact Stress and Lubrication Analysis

This paper presents a theoretical analysis of the maximum contact stress and the lubrication regimes for PEEK (Polyether-ether-ketone) based self-mating cervical total disc arthroplasty. The NuNec(®) cervical disc arthroplasty system was chosen as the study object, which was then analytically modelled as a ball on socket joint. A non-adhesion Hertzian contact model and elastohydrodynamic lubric...

متن کامل

Influence of Layer Thickness and Raster Angle on the Mechanical Properties of 3D-Printed PEEK and a Comparative Mechanical Study between PEEK and ABS

Fused deposition modeling (FDM) is a rapidly growing 3D printing technology. However, printing materials are restricted to acrylonitrile butadiene styrene (ABS) or poly (lactic acid) (PLA) in most Fused deposition modeling (FDM) equipment. Here, we report on a new high-performance printing material, polyether-ether-ketone (PEEK), which could surmount these shortcomings. This paper is devoted to...

متن کامل

High-strength, surface-porous polyether-ether-ketone for load-bearing orthopedic implants.

Despite its widespread clinical use in load-bearing orthopedic implants, polyether-ether-ketone (PEEK) is often associated with poor osseointegration. In this study, a surface-porous PEEK material (PEEK-SP) was created using a melt extrusion technique. The porous layer was 399.6±63.3 μm thick and possessed a mean pore size of 279.9±31.6 μm, strut spacing of 186.8±55.5 μm, porosity of 67.3±3.1% ...

متن کامل

Overview of learning theories and its applications in medical education

Introduction: The purpose of teaching is learning, and learning is related to learning theories. These theories describe and explain how people learn. According to various experts' opinion about learning, many theories emerged. The paper reviewed three major approaches include behaviorism, cognitive and constructive learning and its educational applications in medical science. Methods: this pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Epidemiology and Global Health

سال: 2019

ISSN: 2213-3984

DOI: 10.1016/j.cegh.2019.01.003