PolLux: A new facility for soft x-ray spectromicroscopy at the Swiss Light Source
نویسندگان
چکیده
منابع مشابه
PolLux: a new facility for soft x-ray spectromicroscopy at the Swiss Light Source.
We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energ...
متن کاملA scanning transmission x-ray microscope for materials science spectromicroscopy at the advanced light source
Design and performance of a scanning transmission x-ray microscope ~STXM! at the Advanced Light Source is described. This instrument makes use of a high brightness undulator beamline and extends the STXM technique to new areas of research. After 2.5 years of development it is now an operational tool for research in polymer science, environmental chemistry, and magnetic materials. © 1998 America...
متن کاملX27A—A new hard X-ray micro-spectroscopy facility at the National Synchrotron Light Source
A new hard X-ray micro-spectroscopy beamline has recently been installed at bending-magnet beamline X27A at the National Synchrotron Light Source, where the focus of research is primarily directed towards the environmental, geological and materials science communities. This instrument delivers moderate, 10 mm spatial resolution using achromatic dynamically bent Kirkpatrick–Baez mirrors, in addi...
متن کاملThe MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source
The MYTHEN single-photon-counting silicon microstrip detector has been developed at the Swiss Light Source for time-resolved powder diffraction experiments. An upgraded version of the detector has been installed at the SLS powder diffraction station allowing the acquisition of diffraction patterns over 120 degrees in 2theta in fractions of seconds. Thanks to the outstanding performance of the d...
متن کاملHigh-resolution soft X-ray beamline ADRESS at the Swiss Light Source for resonant inelastic X-ray scattering and angle-resolved photoelectron spectroscopies
The concepts and technical realisation of the high-resolution soft X-ray beamline ADRESS operating in the energy range from 300 to 1600 eV and intended for resonant inelastic X-ray scattering (RIXS) and angle-resolved photoelectron spectroscopy (ARPES) are described. The photon source is an undulator of novel fixed-gap design where longitudinal movement of permanent magnetic arrays controls not...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 2008
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.3021472