Pollutant dispersion in a group of courtyard buildings

نویسندگان

چکیده

As stated by the World Health Organization (WHO), air pollution in urban environment is silent cause for around seven million death worldwide. This due to indoor and outdoor exposure various pollutants emitted built environment: as global trend an increase of population living towns, this issue predicted become even worser. a matter fact, can trapping instead their dispersion. In work, dispersion plume pollutant (carbon monoxide, CO), from chimneystack above roof courtyard group courtyards, investigated. achieved employing ENVI-met software, able model, among others, turbulence environment. Results show, how upstream building harm also downstream buildings.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical analysis of a pollutant dispersion in subsurface soil

A hydraulic scale model was used in a laboratory experiment for the purpose of understanding the characteristics of a pollutant dispersion in subsurface soil. The experimental site was an area near a radioactive waste repository in the Republic of Korea. The hydraulic scale model was designed and manufactured in geometric similarity to the actual site. The tracer 99mTc which has a short half-li...

متن کامل

faculty of psychology and social sciences group of anthropology master thesis in major of anthropology

چکیده پایان نامه (شامل خلاصه، اهداف، روش های اجرا و نتایج به دست آمده): کار جمع آوری گو یش های محلی در سال های اخیر شتاب امیدوار کننده ای به خود گرفته است. شاید از بارزترین اهداف جمع آوری گویش های مختلف، ثبت و ضبط آن، جلوگیری از نابودی و مهمتر از همه حل مشکلات دستوری زبان رسمی باشد. دقت در فرآیند های زبانی گویش های محلی نوع ارتباط مردم نواحی مختلف با پیرامون نشان را به ما نشان خواهد داد. از س...

Transient Simulation of Airflow and Pollutant Dispersion Under Mixing Flow and Buoyancy Driven Flow Regimes in Residential Buildings

The distribution of airflow in a residential building varies with the periodic operation of a heating, ventilating and airconditioning (HVAC) system. Depending on the HVAC fan operation, mixing airflow (fan ON) or stratified airflow (fan OFF) occurs in the space. The objectives of this study are 1) to examine the time needed for room air to stabilize after a central ventilation fan turns ON/OFF...

متن کامل

Pollutant Dispersion in a Developing Valley Cold - Air Pool

Pollutants are trapped and accumulate within cold-air pools, thereby affecting air 5 quality. A numerical model is used to quantify the role of cold-air-pooling processes in 6 the dispersion of air pollution in a developing cold-air pool within an alpine valley under 7 decoupled stable conditions. Results indicate that the negatively buoyant downslope flows 8 transport and mix pollutants into t...

متن کامل

High-resolution pollutant dispersion modelling in contaminated coastal sites.

The recent developments in pollutant measurement methods and techniques necessitate improvements in modelling approaches. The models used so far have been based on seasonally averaged data, which is insufficient for making short-term predictions. We have improved the existing modelling tools for pollutant transport and dispersion on three levels. We significantly refined the numerical grid; we ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Epj Web of Conferences

سال: 2022

ISSN: ['2101-6275', '2100-014X']

DOI: https://doi.org/10.1051/epjconf/202226401013