Polarographic determination of tin and lead in beryllium-copper alloy
نویسندگان
چکیده
منابع مشابه
Determination of Copper (II) and Palladium (II) by Polarographic Methods
Schiff base 2–Hydroxy–5–methoxy Benzaldehyde – Tris [HMBT] Ligand is a new chromogenic reagent have not been used so far for the determination of copper and palladium in trace quantities. Effect of p H on wave height for COPPER[HMBT] PALLADIUM –[HMBT] systems have been studied at p H 7-8.5 and 8.5-11.5 for Copper and Palladium respectively in 0.1 m molar NaNo3 and 0.002 % Triton –x–100 which in...
متن کاملExposure pathway assessment at a copper-beryllium alloy facility.
Controlling beryllium inhalation exposures to comply with regulatory levels (2 micro g m(-3) of air) does not appear to prevent beryllium sensitization and chronic beryllium disease (CBD). Additionally, it has proven difficult to establish a clear inhalation exposure-response relationship for beryllium sensitization and CBD. Thus, skin may be an important route of exposure that leads to berylli...
متن کاملdetermination of olanzapine and thiourea using electrodes modified by dna and film of copper-cobalt hexacyanoferrate & investigation of electro-oxidation of some catechol derivatives in the presence of 4-phenylsemicarbazid
چکیده هدف از این کار بررسی الکترواکسیداسیون کتکول و مشتقات آن در حضور 4-فنیل سمی کاربامازید بوده است اکسیداسیون کتکولها ترکیبات نا پایدار کینونها را تولید می کنند که این ترکیبات می تواند در واکنش مایکل بعنوان پذیرنده نوکلئوفیل عمل نمایند. در ادامه اکسایش کتکولهای (a-c1) را درحضور 4-فنیل سمی کاربامازید در محلول آب/استونیتریل (90/10)بوسیله ولتامتری چرخه ای و کولن متری در پتانسیل ثابت مورد بررسی ...
15 صفحه اولComparison of thermo-mechanical behavior of lead-free copper and tin-lead column grid array packages
Thermo-mechanical behavior of the lead (Pb)-free ceramic copper column grid array (CuCGA) package under accelerated thermal cycling is characterized and compared with the conventional tin–lead (Sn–Pb) ceramic column grid array (CCGA). In situ thermal deformations of the highest DNP (distance to neutral point) copper column is measured for an initial isothermal loading of DT = 75 C and subsequen...
متن کاملPolarographic determination of malononitrile.
A procedure is proposed for the determination of malononitrile by differential pulse polarography in methanolic 0.1M tetraethylammonium iodide/0.001M tetramethylammonium hydroxide as the supporting electrolyte. In this medium malononitrile is chemically converted into an electroactive species. With close control of timing of the steps in the procedure the error of the method is +/-1.5% in the c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BUNSEKI KAGAKU
سال: 1961
ISSN: 0525-1931
DOI: 10.2116/bunsekikagaku.10.1217