Point of Care Testing for Malaria Using LAMP, Loop Mediated Isothermal Amplification

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Point of care testing for malaria using LAMP, loop mediated isothermal amplification.

For over a century the laboratory diagnosis of malaria has relied on visualization of the parasite in blood smears. But microscopy is time and labor consuming and often inaccurate due to the considerable training and experience required. About 2 decades ago, immunochromatographic rapid diagnostic tests (RDTs) were introduced, providing a simpler and more rapid point of care diagnostic. However,...

متن کامل

Malaria Diagnosis by Loop-mediated Isothermal Amplification (lamp) in Thailand.

The loop-mediated isothermal amplification method (LAMP) is a recently developed molecular technique that amplifies nucleic acid under isothermal conditions. For malaria diagnosis, 150 blood samples from consecutive febrile malaria patients, and healthy subjects were screened in Thailand. Each sample was diagnosed by LAMP, microscopy and nested polymerase chain reaction (nPCR), using nPCR as th...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

Determination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran

Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...

متن کامل

Electric LAMP: Virtual Loop-Mediated Isothermal AMPlification

We present eLAMP, a PERL script, with Tk graphical interface, that electronically simulates Loop-mediated AMPlification (LAMP) allowing users to efficiently test putative LAMP primers on a set of target sequences. eLAMP can match primers to templates using either exact (via builtin PERL regular expressions) or approximate matching (via the tre-agrep library). Performance was tested on 40 whole ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Infectious Diseases

سال: 2014

ISSN: 0022-1899,1537-6613

DOI: 10.1093/infdis/jiu253