PO-1020: Better plans and easy plan selection via bi-objective optimization for HDR prostate brachytherapy
نویسندگان
چکیده
منابع مشابه
Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapy.
Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or have long solution times. We decrease the solution time of the existing linear and quadratic dose-ba...
متن کاملPractical considerations for prostate HDR brachytherapy.
PURPOSE A process for prostate high-dose-rate (HDR) brachytherapy was developed and implemented successfully in the community hospital setting. The practical aspects of the program are reviewed and may serve as a foundation for clinics interested in offering this clinical service. METHODS AND MATERIALS A generic needle distribution geometry was established to accommodate target volumes of var...
متن کاملComparison of IPSA and HIPO inverse planning optimization algorithms for prostate HDR brachytherapy
Publications have reported the benefits of using high-dose-rate brachytherapy (HDRB) for the treatment of prostate cancer, since it provides similar biochemical control as other treatments while showing lowest long-term complications to the organs at risk (OAR). With the inclusion of anatomy-based inverse planning opti- mizers, HDRB has the advantage of potentially allowing dose escalation. Amo...
متن کاملA new CT prostate segmentation for CT-based HDR brachytherapy
High-dose-rate (HDR) brachytherapy has become a popular treatment modality for localized prostate cancer. Prostate HDR treatment involves placing 10 to 20 catheters (needles) into the prostate gland, and then delivering radiation dose to the cancerous regions through these catheters. These catheters are often inserted with transrectal ultrasound (TRUS) guidance and the HDR treatment plan is bas...
متن کاملRobust optimization of dose-volume metrics for prostate HDR-brachytherapy incorporating target volume delineation uncertainties
In radiation therapy planning, uncertainties in target volume definition yield a risk of underdosing the tumor. The classical way to prevent this in the context of external beam radiotherapy (EBRT) has been to expand the clinical target volume (CTV) with an isotropic margin to obtain the planning target volume (PTV). However, the EBRT-based PTV concept is not directly applicable to brachytherap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Radiotherapy and Oncology
سال: 2018
ISSN: 0167-8140
DOI: 10.1016/s0167-8140(18)31330-6