PO-0921: Dose considerations of IGRT using MV projection and MV CBCT on a prototype linear accelerator
نویسندگان
چکیده
منابع مشابه
Mega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.
Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...
متن کاملFeasibility of MV CBCT‐based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT‐based dose calculations
Unlike scheduled radiotherapy treatments, treatment planning time and resources are limited for emergency treatments. Consequently, plans are often simple 2D image-based treatments that lag behind technical capabilities available for nonurgent radiotherapy. We have developed a novel integrated urgent workflow that uses onboard MV CBCT imaging for patient simulation to improve planning accuracy ...
متن کاملDose Rate Influence on Deep Dose Deposition Using a 6 MV X-Ray Beam From a Linear Accelerator
Linear accelerators used in radiation therapy treatments usually provide the capability of irradiating with different dose rates. The medical physicist may choose arbitrary the dose rate to use, although the relative biological effectiveness (RBE) varies with this physical parameter. In this work the measurements of absorbed dose of the x-ray beams from a Varian 6 MV linear accelerator CLINAC 6...
متن کاملPhantom-based evaluation of dose exposure of ultrafast combined kV-MV-CBCT towards clinical implementation for IGRT of lung cancer
PURPOSE Combined ultrafast 90°+90° kV-MV-CBCT within single breath-hold of 15s has high clinical potential for accelerating imaging for lung cancer patients treated with deep inspiration breath-hold (DIBH). For clinical feasibility of kV-MV-CBCT, dose exposure has to be small compared to prescribed dose. In this study, kV-MV dose output is evaluated and compared to clinically-established kV-CBC...
متن کاملA Monte Carlo study on Photoneutron Spectrum around Elekta SL75/25 18 MV linear accelerator
Medical linear accelerators are one of the most widespread methods for cancer treatment. Despite their advantages, unwanted photoneutrons are produced by high energy linacs. This photoneutrons are as undesired doses to patients and a significant problem for radiation protection of the staffs and patients. Photoneutrons radiological risk must be evaluated because of their high LET and range.in o...