Golden beam data for proton pencil-beam scanning.
Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...
متن کاملDynamic Delivery Planning in Iba Proton Pencil Beam
Pencil Beam Scanning is a dynamic beam delivery system developed for proton therapy. The radiation field necessary to reach in a fast and robust way a prescribed 3D dose distribution is obtained by accurately controlling both the extraction of the beam from a 235 MeV accelerator and the motion of the beam spot thanks to scanning magnets. This paper focuses on the trajectory planning aspect of t...
متن کاملA Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4.
This work proposes a generic method for modeling scanned ion beam delivery systems, without simulation of the treatment nozzle and based exclusively on beam data library (BDL) measurements required for treatment planning systems (TPS). To this aim, new tools dedicated to treatment plan simulation were implemented in the Gate Monte Carlo platform. The method was applied to a dedicated nozzle fro...
متن کاملComparison of multi‐institutional Varian ProBeam pencil beam scanning proton beam commissioning data
PURPOSE Commissioning beam data for proton spot scanning beams are compared for the first two Varian ProBeam sites in the United States, at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (SPTC). In addition, the extent to which beams can be matched between gantry rooms at MPTC is investigated. METHOD Beam data for the two sites were acquired with independent dos...
متن کاملFast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model
The highly conformal dose distributions produced by scanned proton pencil beams (PBs) are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy. The ability to calculate the dose in real-time as it is being delivered would enable, for example, online dose monitoring, and is therefore highly desirable. We have previously described an implementation of a...