PO-0794: Evaluating the usefulness of EPID for daily output verification by comparison to ionization chamber measurements
نویسندگان
چکیده
منابع مشابه
the evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine
abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...
15 صفحه اولstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)
Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...
متن کاملCamera based EPID dosimetric verification of radiation treatments
Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context. Materials and Methods: In this study, ...
متن کاملEvaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...