PO-05-021 HYPERTROPHIC CARDIOMYOPATHY INCREASES THE RISKS OF BRADYARRHYTHMIA AND PACEMAKER IMPLANTATION

نویسندگان

چکیده

Previous studies of bradycardia complicating hypertrophic cardiomyopathy (HCM) have been reported in rare patients. Whether HCM is associated with bradyarrhythmia, leading to permanent pacemaker (PPM) implantations, remains unclear. We aimed explore the risks bradyarrhythmia and subsequent PPM implantation patients HCM. Patients newly diagnosed were identified from Taiwan National Health Insurance Research Database 2012 2017. A control cohort was selected by matching age gender a 1:1 ratio study (Panel A). The primary outcomes occurrence bradyarrythmia or implantation. multivariate Cox hazards regression model used evaluate hazard (HR) for outcomes. total 12,094 (n=6,047 each group) mean 63.1±14.8 years analyzed. During follow-up period 3.17±1.77 years, percentage higher group (3.3%) than that (0.5%) (p<0.001). receiving also (4.6%) (0.3%) After adjusting baseline variables, increased (adjusted HR: 5.45, 95% confidence interval (CI) 3.61-8.21, p<0.001) 14.34, CI 8.73-23.57, B C). In this cohort, presence AF 1.62; 1.04-2.54, p=0.034) 1.67; 1.13-2.48, p=0.011). further

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe cardiac conduction disturbances and pacemaker implantation in patients with hypertrophic cardiomyopathy.

The aims of this study were to determine the prevalence of severe cardiac conduction disturbances in a cohort of 451 patients with hypertrophic cardiomyopathy and to describe the characteristics of, and outcomes in, those who required a permanent pacemaker. A pacemaker was implanted in 48 patients (11%): 20 had sinus node dysfunction and 28 had an atrioventricular conduction disturbance. Primar...

متن کامل

Takotsubo Cardiomyopathy after Permanent Pacemaker Implantation

A 78-year-old woman presented to our emergency room because of complete atrioventricular block. The patient experienced significant psychophysical stress during pacemaker implantation due to fear of operation. Acute lung edema occurred four hours after permanent pacemaker implantation. Coronary angiography showed no significant coronary artery stenosis and left ventriculography revealed typical...

متن کامل

Does pacemaker implantation provide long-term benefits in severe obstructive hypertrophic cardiomyopathy?

INTRODUCTION AND OBJECTIVES About 25% of patients with obstructive hypertrophic cardiomyopathy (HCM) remain symptomatic despite optimal medical treatment. Some may benefit from pacemaker implantation. The aim of this study was to determine the effect of pacemaker implantation on the left ventricular outflow tract (LVOT) gradient, the maximum thickness of the left ventricle, and functional capac...

متن کامل

Pacemaker therapy in hypertrophic obstructive cardiomyopathy: still awaiting the evidence.

Correspondence: W.J. McKenna, MD, The Heart Hospital, University College London Hospitals, 16-18 Westmoreland Street, London W1G 8PH, United Kingdom E-mail: [email protected] The initial descriptions of hypertrophic cardiomyopathy (HCM) focused on the presence of left ventricular (LV) outflow tract obstruction as a defining feature of the condition.1-6 The use of echocardiography, which ...

متن کامل

Hypertrophic cardiomyopathy and tachyarrhythmias detected by a pacemaker.

A 56-year-old man came to the Pacemaker Clinic for his regular pacemaker control. He had experienced a syncopal episode in the previous week. He had a previous diagnosis of non-obstructive hypertrophic cardiomyopathy. Due to a previous syncope and documented 2:1 infrahisian block, a dual-chamber permanent pacemaker had been implanted a few years before. The device was interrogated, showing seve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Heart Rhythm

سال: 2023

ISSN: ['1556-3871', '1547-5271']

DOI: https://doi.org/10.1016/j.hrthm.2023.03.1462