PMT gain calibration and monitoring based on highly compressed hit information in KM3NeT

نویسندگان

چکیده

The cubic-kilometre neutrino telescope, which consists of large-scale 3D-arrays photomultiplier tubes (PMTs) currently under construction on the Mediterranean seabed, relies accurate calibration procedures in order to answer its science goals. These proceedings present gain method used KM3NeT, is based highly compressed PMT hit information. In particular, it shown that gains can be tuned within 2% nominal value, measured single photoelectron time-over-threshold distribution each PMT.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PMT Calibration in the XENON 1T Demonstrator

XENON Dark Matter Project searches for the dark matter candidate, the Weakly Interacting Massive Particle (WIMPs). All XENON experiments use a time projection chamber (TPC) to detect nuclear recoils resulting from WIMP-nuclei scattering. Photomultiplier tubes (PMTs) read out the signal from the scintillation and ionization of the xenon triggered by the nuclear recoils. This paper details PMT ga...

متن کامل

task-based language teaching in iran: a mixed study through constructing and validating a new questionnaire based on theoretical, sociocultural, and educational frameworks

جنبه های گوناگونی از زندگی در ایران را از جمله سبک زندگی، علم و امکانات فنی و تکنولوژیکی می توان کم یا بیش وارداتی در نظر گرفت. زبان انگلیسی و روش تدریس آن نیز از این قاعده مثتسنی نیست. با این حال گاهی سوال پیش می آید که آیا یک روش خاص با زیر ساخت های نظری، فرهنگی اجتماعی و آموزشی جامعه ایرانی سازگاری دارد یا خیر. این تحقیق بر اساس روش های ترکیبی انجام شده است.پرسش نامه ای نیز برای زبان آموزان ...

Time calibration system for the KM3NeT deep sea neutrino telescope

In this contribution we review the time calibration system proposed for the future underwater KM3NeT neutrino telescope. Building on the experience gained with the pilot projects, ANTARES, NEMO and NESTOR, and the results in-situ from the ANTARES Optical Beacons, we propose a decoupled optical system, based on LEDs and lasers, to perform an intra-line and inter-line relative time calibration. T...

متن کامل

The Calibration Units of the KM3NeT neutrino telescope

KM3NeT is a network of deep-sea neutrino telescopes to be deployed in the Mediterranean Sea that will perform neutrino astronomy and oscillation studies. It consists of three-dimensional arrays of thousands of optical modules that detect the Cherenkov light induced by charged particles resulting from the interaction of a neutrino with the surrounding medium. The performance of the neutrino tele...

متن کامل

the comparative impact of prompts and recasts in processing instruction versus meaningful output-based instruction on efl learners’ writing accuracy

the purpose of the present study was to see which one of the two instruction-processing instruction (pi) and meaningful output based instruction (mobi) accompanied with prompt and recast- is more effective on efl learners’ writing accuracy. in order to homogenize the participants in term of language proficiency a preliminary english test (pet) was administrated between 74 intermediate students ...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2021

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/16/09/c09011