Plasticized PVC Membrane Modified Electrodes: Voltammetry of Highly Hydrophobic Compounds
نویسندگان
چکیده
منابع مشابه
Highly selective PVC-membrane electrodes based on Co(II)-Salen for determination of nitrite ion.
A cobalt(II) derivative was used as a suitable ionophore for the preparation of a polymeric membrane nitrite-selective electrode. The electrode reveals a Nemstian behavior over a very wide NO2- ion concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) and a very low detection limit (5.0 x 10(-7) M). The potentiometric response is independent of the pH of solution in the pH range 4.0-9.5. The electr...
متن کاملHydrophobic Compounds Reshape Membrane Domains
Cell membranes have a complex lateral organization featuring domains with distinct composition, also known as rafts, which play an essential role in cellular processes such as signal transduction and protein trafficking. In vivo, perturbations of membrane domains (e.g., by drugs or lipophilic compounds) have major effects on the activity of raft-associated proteins and on signaling pathways, bu...
متن کاملComparison of the vanadyl-selective electrodes prepared by sol–gel and PVC membrane techniques
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
متن کاملGlycosylated metalloporphyrins as neutral carriers for PVC membrane electrodes.
In this paper, the synthesis of a novel ionophore, chloro[5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-beta-D-glucopyranosyl)-1-O-phenyl]porphinato]manganese (MnT(o-glu)PPCl), and its application as a neutral carrier for a PVC membrane electrode are described. The MnT(o-glu)PPCl-based PVC membrane electrode shows a potentiometric responses to SCN- over a concentration range of 3.4 x 10(-7) - 1.0 ...
متن کاملTriiodide PVC membrane electrodes based on charge-transfer complexes.
Three new electrodes were prepared by incorporating two different charge-transfer complexes and amino crown ether into plasticized PVC membranes. The electrodes showed Nernstian response to triiodide ion over the activity range from 1.0 x 10(-5) to 1.0 x 10(-1) mol x L(-1) with detection limits at approximately 1.0 x 10(-6) mol x L(-1). The resulting electrodes have fast response times (20-30 s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Membranes
سال: 2020
ISSN: 2077-0375
DOI: 10.3390/membranes10090202