PLASTIC CAPACITY OF BOLTED RHS FLANGE-PLATE JOINTS UNDER AXIAL TENSION
نویسندگان
چکیده
منابع مشابه
Mechanical Behavior of BFRP-Steel Composite Plate under Axial Tension
Combining the advantages of basalt fiber-reinforced polymer (BFRP) material and steel material, a novel BFRP-steel composite plate (BSP) is proposed, where a steel plate is sandwiched between two outer BFRP laminates. The main purpose of this research is to investigate the mechanical behavior of the proposed BSP under uniaxial tension and cyclic tension. Four groups of BSP specimens with four d...
متن کاملEvaluation of stress distribution in bolted steel angles under tension
The stress distribution in the vicinity of connections in a bolted steel angle is non-uniform because of the coupled effects of connection eccentricity, shear lag and stress concentrations. Although, some researchers have attempted finite element analysis, stipulations in various codes and specifications regarding the design of angle tension members are primarily based on the experimental studi...
متن کاملBolted Joints in Laminated Composites
Expressions were presented which can be used to estimate the strengths of continuous fiber reinforced composite laminates containing pin-loaded holes. The expressions apply to laminates containing either a single pin loaded hole, a single row of pin loaded holes, or two parallel rows of pin loaded holes.
متن کاملIdentification of Bolted Joints through Laser Vibrometry
We present a new technique for identifying the dynamics of bolted joints. The technique relies on the comparison of the overall dynamics of the bolted structure to that of a similar but unbolted one. The di!erence in the dynamics of the two systems can be attributed solely to the joint; modelling this di!erence in the dynamics enables us to construct a non-parametric model for the joint dynamic...
متن کاملUltimate Axial Load Capacity of V-band Clamp Joints
Band clamps with a flat bottomed V-section are used to connect a pair of circular flanges to provide a joint with significant axial strength. Despite the wide application of V-band clamps, their behaviour is not fully understood and the ultimate axial strength is currently only available from physical testing. This physical testing has indicated that the ultimate strength is determined by two d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures and Technologies
سال: 2016
ISSN: 2029-882X,2029-8838
DOI: 10.3846/2029882x.2016.1216806