UV-Cured Inkjet-Printed Silver Gate Electrode with Low Electrical Resistivity

Inkjet-printed silver gate electrode with low electrical resistivity was fabricated by UV curing method. By adjusting the UV curing time and the distance between the samples and UV lamp, the effects of UV curing conditions on the electrical resistivity of the silver films were studied, and the lowest electrical resistivity of 6.69 × 10-8 Ω·m was obtained. Besides, the UV-cured silver films have...

متن کامل

Low Temperature Resistivity

The temperature dependence of electrical resistivity was measured for three materials: a conductor (copper), a semiconductor (a carbon resistor), and a doped semiconductor (a pn junction). As expected, the resistance of the copper sample decreased with temperature and the resistance of the carbon resistor increased with temperature. The temperature coefficient of resistance of Cu was calculated...

متن کامل

Sub-seafloor resistivity sensing using a vertical electrode configuration

There is growing interest in marine direct current (DC) resistivity methods for sub-seafloor exploration of a broad range of geophysical and geological targets. To address this, we have developed a new marine DC method with a vertical electrode configuration (VEC). Compared to conventional marine DC methods that use a horizontal electrode configuration, the shape and position of our VEC cable c...

متن کامل

The use of multi-electrode resistivity imaging in gravel prospecting

We investigated the potential of using a 24-electrode resistivity imaging apparatus for rapid reconnaissance surveys for natural-aggregate accumulation. The surveys were first calibrated at sites with known geometry of sand and gravel layers, which showed that subsurface accumulation of coarse material was accurately resolved with both 2and 4-m electrode spacing. The inverted absolute resistivi...

متن کامل

Fast computation of optimized electrode arrays for 2D resistivity surveys

Four different methods to automatically select an optimal set of array configurations that gives the maximum resolution of the subsurface with a limited number of measurements for 2D electrical imaging surveys were tested. The first method (CR method) directly calculates the change in the model resolution for each new array added to the base data set, and uses this to select array configuration...