Plane-constraint-based calibration method for a galvanometric laser scanner
نویسندگان
چکیده
منابع مشابه
Modeling and Calibration of a Novel One-Mirror Galvanometric Laser Scanner
A laser stripe sensor has limited application when a point cloud of geometric samples on the surface of the object needs to be collected, so a galvanometric laser scanner is designed by using a one-mirror galvanometer element as its mechanical device to drive the laser stripe to sweep along the object. A novel mathematical model is derived for the proposed galvanometer laser scanner without any...
متن کاملKinematic calibration using a plane constraint
This work deals with closed-loop calibration methods where the robot endpoint is constrained to lie on a plane. Previously published calibration approaches are shown to have certain weaknesses. A new solution is given using DH and Hayati notations and standard nonlinear least squares optimization. The procedure is extended via the Implicit Loop Method, which takes input noise into account. Pose...
متن کاملArticleModeling and Calibration of a Novel One-Mirror Galvanometric Laser ScannerChengyi Yu 1
A laser stripe sensor has limited application when a point cloud of geometric samples on the surface of the object needs to be collected, so a galvanometric laser scanner is designed by using a one-mirror galvanometer element as its mechanical device to drive the laser stripe to sweep along the object. A novel mathematical model is derived for the proposed galvanometer laser scanner without any...
متن کاملA Laser Range Scanner Designed for Minimum Calibration Complexity
Laser range scanners are a popular method for acquiring three-dimensional geometry due to their accuracy and robustness. Maximizing scanner accuracy while minimizing engineering costs is a key challenge to future scanner designs. Engineering costs arise from both expensive components and difficult calibration
متن کاملA Mathematical Model and Calibration Procedure for Galvanometric Laser Scanning Systems
Laser galvanometric scanning systems are commonly used in various fields such as three dimensional scanning, medical imaging, material processing, measurement devices and laser display systems. The systems of such kind suffer from distortions. On top of that they do not have a center of projection, which makes it impossible to use common projector calibration procedures. The paper presents a no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Mechanical Engineering
سال: 2018
ISSN: 1687-8140,1687-8140
DOI: 10.1177/1687814018773670