We report a case of a 42-year-old male who developed generalized tonic-clonic seizure with sudden, brief decrease in bispectral index (BIS) value while undergoing emergency kidney transplantation. Few reports have been made on intraoperative pitfall of BIS value associated with seizure. This case report suggests seizure should be taken into account as a reason for such brief fall of BIS, especi...

متن کامل

Pitfall of bispectral index during intraoperative seizure

bispectral index (BIS) value while undergoing emergency kidney transplantation. Few reports have been made on intraoperative pitfall of BIS value associated with seizure. This case report suggests seizure should be taken into account as a reason for such brief fall of BIS, especially while under general anesthesia or in other specific cases in which clinical signs of seizure are unseen. (Korean...

متن کامل

Case report: A pitfall in dermatopathology

A 47-year-old man with 3 years history of a pruritic plaque, 1×3 cm on his left leg attended a dermatology clinic. An incisional biopsy was done with the differential diagnoses of: 1) Hypertrophic lichen planus, 2) Lichen simplex chronicus, 3) Psoriasis, 4) Bowen's disease. A diagnosis of “Fibroepithelioma” was suggested by histopathologist who was not compatible with clinical diagnosis. Carefu...

متن کامل

A case report of pyridoxine dependent seizure

pyridoxine dependent seizure have been recornized as a rare and important cause of intractable seizure in neonates and infants.prompt diagnosis and treatment can stop and prevent these seizure and consequential developmental disabilities.furthermore it can eliminate the unnecessary administration of anticonvulsant medications and thier side effects.the paitient was 7 months old infant who was r...

متن کامل

Usefulness of the bispectral index during cardiopulmonary resuscitation -A case report-

The usefulness of using the bispectral index (BIS) for monitoring during cardiopulmonary resuscitation (CPR) is not clearly understood. However, BIS has been a popular anesthetic monitoring device used during operations. The case presented is of a pregnant woman going into cardiac arrest due to an amniotic fluid embolism during a Cesarean section. CPR was performed, but neither the return of sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Korean Journal of Anesthesiology

سال: 2013

ISSN: 2005-6419,2005-7563

DOI: 10.4097/kjae.2013.65.5.449