Pin-Gap Correction of Coaxial Calibration Standards for TRL or LRL Calibration
نویسندگان
چکیده
In this paper, a novel method is proposed by which to correct the pin gaps of coaxial calibration standards for Thru-Reflect-Line (TRL) or Line-Reflect-Line (LRL) calibration. This post-process in pin-gap correction applied measured S-parameters device under test (DUT) after TRL LRL It based on perturbation equations derived from sensitivity-coefficient approach. These enable us obtain quantity DUT-S-parameter due gaps. We verify simulation 2.4 mm line, and result shows that works successfully. Because equations, smaller gap, better results. Nevertheless, we can achieve sufficient results within range at least 10 times nominal value. addition, play role impedance renormalization, even though two lines have different characteristic impedance. Finally, demonstrate kit through measurement.
منابع مشابه
Test Structures and Techniques for On-Wafer CMOS TRL Calibration
In this paper, we demonstrate for the first time a TRL calibration kit fabricated in CMOS technology. To fulfill a basic requirement of high probe-isolation of the TRL method, we have based all fabricated calibration standards on a shield-based measuring fixture that heavily reduces the effects of the semiconducting substrate. We analyze the electrical performance of the standards, including th...
متن کاملCalibration of Large Square Standards
In this paper the principle and device NME 90 for large square standards calibration is described. The self-calibration methods of measurement are used. They allow very low uncertainty of the square calibration with mathematical elimination of measuring column straightness deviations. The process of measurement is full automated and controlled by PC, which collects and evaluates measured data. ...
متن کاملCalibration of dissipation factor standards
Working standards for dissipation factor (D) obtained by connecting a shielded three-tenninal capacitor in series with a shielded precision resistor have been developed for calibration purposes. Precision conductance boxes have been built for use with a single three-tenninallOOO pF gas capacitor standard to create dissipation factor standards having values from 2 x 10-5 to 1 X 10-2. The design ...
متن کاملCamera Calibration with Two Arbitrary Coaxial Circles
We present an approach for camera calibration from the image of at least two circles arranged in a coaxial way. Such a geometric configuration arises in static scenes of objects with rotational symmetry or in scenes including generic objects undergoing rotational motion around a fixed axis. The approach is based on the automatic localization of a surface of revolution (SOR) in the image, and it...
متن کاملRadon Measurement Standards and Calibration
This issue of the Journal of Research of the National Institute of Standards and Technology resulted from a one-half day seminar devoted to descriptions of the current status of the metrology of radon in international laboratories specializing in that area. The seminar, held June 5, 1989, at the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Federal Republic of Germany was co-sponso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Access
سال: 2022
ISSN: ['2169-3536']
DOI: https://doi.org/10.1109/access.2022.3162248