Pile Capacity Calculation by using SPT and CPT Data
نویسندگان
چکیده
منابع مشابه
Evaluation of reliability index and safety factors for pile load capacity estimation using CPT results
The reliability index is an important reliability parameter that is necessary for the development of reliability-based geotechnical design. Both the factor of safety (FS) and the reliability index (β) represent safety margin of structures against either failure or limit state. In this study, the reliability index is analyzed and evaluated in reference to the factor of safety currently adopted i...
متن کاملComparision of Methods for Determining Bearing Capacity of Piles Using Standard Penetration Test (SPT) Data
In recent years, determining bearing capacity of piles from in-situ testing data as a complement to static and dynamic analysis has been used by geotechnical engineers. In this paper, different approaches for estimating bearing capacity of piles from SPT data are studied and compared. A new method based on N value from SPT is presented. Data averaging, 
failure zone and plunging failure of p...
متن کاملComparision of Methods for Determining Bearing Capacity of Piles Using Standard Penetration Test (SPT) Data
In recent years, determining bearing capacity of piles from in-situ testing data as a complement to static and dynamic analysis has been used by geotechnical engineers. In this paper, different approaches for estimating bearing capacity of piles from SPT data are studied and compared. A new method based on N value from SPT is presented. Data averaging, failure zone and plunging failure of pil...
متن کاملA Method for Predicting Pile Capacity Using Cone Penetration Test Data
The massive construction in poor lands has encouraged engineers to use deep foundations in order to transfer superstructure loads to the subsoil. Since soil excavation, sampling, and laboratory testing as a part of site investigation are relatively difficult, in-situ tests such as cone penetration test (CPT) as a very informative test may be recommended. The CPT has been widely used in engineer...
متن کاملCALCULATION OF RESIDUAL VOLUME BY SPIROMETRIC DATA
ABSTRACT Background: The current practice to measure RV is either by BPG or helium dilution methods which may not be available in all clinics due to their cost. Methods: This paper outlines a method for both direct and indirect calculation of RV via PFT with acceptable sensitivity (81 %, 60% ), specificity (71 %, 94%) and validity (76%, 78%) for obstructive and restrictive lung disease respect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Academic Perspective Procedia
سال: 2019
ISSN: 2667-5862
DOI: 10.33793/acperpro.02.03.153