PICOSECOND PULSE RADIOLYSIS OF LIQUIDn-ALKANES
نویسندگان
چکیده
منابع مشابه
The LEAF picosecond pulse radiolysis facility at Brookhaven National Laboratory
The BNL Laser-Electron Accelerator Facility (LEAF) uses a laser-pulsed photocathode, radio-frequency electron gun to generate ù7 ps pulses of 8.7 MeV electrons for pulse radiolysis experiments. The compact and operationally simple accelerator system includes synchronized laser pulses that can be used to probe or excite the electron-pulsed samples to examine the dynamics and reactivity of chemic...
متن کاملDevelopment of a New Picosecond Pulse Radiolysis System by Using Femtosecond Laser Synchronized with Picosecond Electron Beams
A new picosecond pulse radiolysis system for the absorption spectroscopy to observe ultra fast phenomena was developed. The system was composed of a 38 MeV picosecond electron L-band linac for the irradiation source and a femtosecond laser system for the analyzing light. The laser pulse was synchronized with the electron pulse by using the common radio frequency. The timeresolution of the syste...
متن کاملIsir Subpicosecond Pulse Radiolysis System
The highest time resolution of the pulse radiolysis had remained about 30 ps since the late 1960’s. To make clear the primary processes in the radiation chemistry and physics within 30 ps, we developed a stroboscopic pulse radiolysis system for the absorption spectroscopy with the time resolution of 2.0 ps (10-90% rise time). The time resolution of 2.0 ps was estimated from the time-dependent b...
متن کاملPicosecond microwave pulse generation
Picosecond duration X-band microwave pulses have been generated using a laser-activated photoconductive switch. These pulses have been used to observe the microwave reflection from optically excited germanium. The reflection measurements indicate that the microwave pulse has a full width at half-maximum of 50 ps and is synchronized with picosecond precision to the laser pulse. A high-resolution...
متن کاملPulse radiolysis of aqueous thiocyanate solution.
The pulse radiolysis of N(2)O saturated aqueous solutions of KSCN was studied under neutral pH conditions. The observed optical absorption spectrum of the SCN(*) radical in solution is more complex than previously reported, but it is in good agreement with that measured in the gas phase. Kinetic traces at 330 and 472 nm corresponding to SCN(*) and (SCN)(2)(*-), respectively, were fit using a Mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemistry Letters
سال: 1982
ISSN: 0366-7022,1348-0715
DOI: 10.1246/cl.1982.1883