Physiological basis of vascular autocalibration (VasA): Comparison to hypercapnia calibration methods
نویسندگان
چکیده
منابع مشابه
Physiological basis of vascular autocalibration (VasA): Comparison to hypercapnia calibration methods
PURPOSE The statistical power of functional MRI (fMRI) group studies is significantly hampered by high intersubject spatial and magnitude variance. We recently presented a vascular autocalibration method (VasA) to account for vascularization differences between subjects and hence improve the sensitivity in group studies. Here, we validate the novel calibration method by means of direct comparis...
متن کاملA Unification of Autocalibration Methods
This paper describes a unified theory for autocalibration of a moving camera. The camera models can be 2D projective, 2D affine camera and 1D projective projections. The scenes can be either non-planar scenes or planar scenes and the camera may also undergoes a pure rotation. All these cases are unified into the same framework based on the direction bases. Each formulation on the direction base...
متن کاملon the comparison of keyword and semantic-context methods of learning new vocabulary meaning
the rationale behind the present study is that particular learning strategies produce more effective results when applied together. the present study tried to investigate the efficiency of the semantic-context strategy alone with a technique called, keyword method. to clarify the point, the current study seeked to find answer to the following question: are the keyword and semantic-context metho...
15 صفحه اولMultivariate Calibration Stability: a Comparison of Methods
In the multivariate calibration framework we revisit and investigate the prediction performance of three high-dimensional modeling strategies: partial least squares, principal component regression and P-spline signal regression. Specifically we are interested in comparing the stability and robustness of prediction under differing conditions, e.g. training the model under one temperature and usi...
متن کاملComparison of Calibration Methods for Tristimulus Colorimeters
Uncertainties in source color measurements with a tristimulus colorimeter are estimated for calibration factors determined, based on a known source spectral distribution or on accurate measurements of the spectral responsivities of the colorimeter channels. Application is to the National Institute of Standards and Technology (NIST) colorimeter and an International Commission on Illumination (CI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2016
ISSN: 0740-3194
DOI: 10.1002/mrm.26494