Phase Shifting Transformer Electromagnetic Model Dedicated for Power System Protection Testing in a Transient Condition

نویسندگان

چکیده

Complex phase shifting transformer protection scheme and complexity of the object itself created a need to use simulation programs for their analysis. Often (PST) are modeled as simplified series impedance quadrature voltage source which cannot be used power system analysis, especially in transient condition. Therefore, procedure building realistic PST model was presented by using available models with calculation parameters including interconnections between units. Paper consist calculations based on case study symmetrical dual-core example. Additionally, theoretical background principle, operation, impact were introduced numerus examples verification.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Stability Improvement Of Power System With Phase Shifting Transformer

Transient stability of a power system is concerned with the system’s ability to remain in synchronism after the disturbance is cleared. Occurrence of a fault in a power system causes transients. The disturbances subjected to the system may be occurrence of fault, sudden change in load etc. This paper describes the improvement of transient stability with phase shift insertion by phase shifting t...

متن کامل

Simulation Research on Photovoltaic Power System Electromagnetic Transient Model

With an increasing number of photovoltaic (PV) power stations integrated into the power grid, a model which is suitable to be used in the power system electromagnetic transient simulation is required. So in this paper, a detailed PV power system model is provided. In the model, the core components, such as PV array and inverter are all considered. Then in a certain case, which contains a PV pow...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

An adaptive distance protection scheme in the presence of phase shifting transformer

Distance relays detect transmission line faults and their locations by measuring the voltage and the current signals. Also, phase shifting transformers (PSTs) are used to control the power flow in electrical power systems. PSTs protect transmission lines from thermal overloading, improve the stability of transmission system and control the power flow between different networks. Unfortunately, e...

متن کامل

FACTS Devices Allocation Using a Novel Dedicated Improved PSO for Optimal Operation of Power System

Flexible AC Transmission Systems (FACTS) controllers with its ability to directly control the power flow can offer great opportunities in modern power system, allowing better and safer operation of transmission network. In this paper, in order to find type, size and location of FACTS devices in a power system a Dedicated Improved Particle Swarm Optimization (DIPSO) algorithm is developed for de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14030627