Phase-Shifted Full Bridge(PSFB) DC/DC Converter with a Hold-up Time Compensation Circuit for Information Technology (IT) Devices

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a New Resonant Converter Circuit for Reluctance

The purpose of this paper is to introduce a different type of converter circuit used to drive switched reluctance motors. It continues with detailed discussion on the resonant converter armed at minimizing or eliminating the transistors switching losses. Finally the drive has been tested on a disc-type reluctance motor for the perfomance and functionality.

متن کامل

LPV Gain-scheduling Control for a Phase-shifted PWM Full-bridge Soft Switched Converter

This paper presents an output feedback LPV gain-scheduling control design for a class of PSPWM full-bridge power converters. The design starts with an averaged model of the converter with adequate complexity. One main contribution of this work is to demonstrate how to reformulate the averaged model into an LPV one. A gain-scheduling controller can then be synthesized taking advantage of the des...

متن کامل

Digital Control of Secondary Active Clamp Phase-shifted Full-bridge Converter

A DSP-based self-adaptive proportional-integral (PI) controller to control a DC-DC converter is proposed in this paper. Full-bridge topology is adopted here to obtain higher power output capability and higher conversion efficiency. The converter adopts zero-voltage-switching (ZVS) technique to reduce conduction losses. A parallel secondary active clamp circuit is added to deal with voltage over...

متن کامل

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Transactions of the Korean Institute of Power Electronics

سال: 2013

ISSN: 1229-2214

DOI: 10.6113/tkpe.2013.18.5.501