Phase retrieval through focus variation for ultra-resolution in field-emission transmission electron microscopy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Stochastic Algorithms for Phase Retrieval in High Resolution Transmission Electron Microscopy

The usefulness of stochastic algorithms to retrieve the exit-plane wave function from periodic high-resolution electron microscopic images is investigated. In contrast to “classical” focal series reconstruction methods which need approximately twenty input images, fully non-linear reconstructions of periodic wave functions are possible in most cases from only two images using stochastic algorit...

متن کامل

Thermal magnetic field noise limits resolution in transmission electron microscopy.

The resolving power of an electron microscope is determined by the optics and the stability of the instrument. Recently, progress has been obtained towards subångström resolution at beam energies of 80 kV and below but a discrepancy between the expected and achieved instrumental information limit has been observed. Here we show that magnetic field noise from thermally driven currents in the con...

متن کامل

High-resolution transmission electron microscopy

High-resolution transmission electron microscopy (HRTEM) has been widely and effectively used for analyzing crystal structures and lattice imperfections in various kinds of advanced materials on an atomic scale. This is especially the case for high Tc superconductors (HTSCs). The most characteristic feature in crystal structures of HTSCs is that there is a common structural element, a CuO2 plan...

متن کامل

Volta potential phase plate for in-focus phase contrast transmission electron microscopy.

We describe a phase plate for transmission electron microscopy taking advantage of a hitherto-unknown phenomenon, namely a beam-induced Volta potential on the surface of a continuous thin film. The Volta potential is negative, indicating that it is not caused by beam-induced electrostatic charging. The film must be heated to ∼ 200 °C to prevent contamination and enable the Volta potential effec...

متن کامل

Domino phase-retrieval algorithm for structure determination using electron diffraction and high-resolution transmission electron microscopy patterns.

Direct-method formalism to determine atomic structures using electron diffraction data is here aimed at a general solution of the phase-retrieval problem, consequently combining electron diffraction (ED) and high-resolution transmission electron microscopy (HRTEM) patterns in a 'domino' fashion. While there are similarities to conventional (kinematical) direct methods, there remain major differ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Letters

سال: 1992

ISSN: 0031-9007

DOI: 10.1103/physrevlett.69.3743