Phase Plate STEM Imaging Using Two Dimensional Electron Detector

نویسندگان
چکیده

منابع مشابه

Quadrature phase detector using two-mode waveguides.

We present a novel design for quadrature phase detection utilizing two-mode optical waveguides for optical interferometric systems. A pair of interferometric signals having quadrature optical phase information can be obtained from the near-field and far-field patterns of a two-mode waveguide output. The operational principle is based on a pi/2 differential phase shift between two modal beams oc...

متن کامل

4D STEM: High efficiency phase contrast imaging using a fast pixelated detector

Phase contrast imaging is widely used for imaging beam sensitive and weak phase objects in electron microscopy. In this work we demonstrate the achievement of high efficient phase contrast imaging in STEM using the pnCCD, a fast direct electron pixelated detector, which records the diffraction patterns at every probe position with a speed of 1000 to 4000 frames per second, forming a 4D STEM dat...

متن کامل

Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector.

A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electr...

متن کامل

Spectral-domain phase microscopy with improved sensitivity using two-dimensional detector arrays.

In this work we demonstrate the use of two-dimensional detectors to improve the signal-to-noise ratio (SNR) and sensitivity in spectral-domain phase microscopy for subnanometer accuracy measurements. We show that an increase in SNR can be obtained, from 82 dB to 105 dB, using 150 pixel lines of a low-cost CCD camera as compared to a single line, to compute an averaged axial scan. In optimal mec...

متن کامل

Two-Phase Nanofluid Thermal Analysis over a Stretching Infinite Solar Plate Using Keller Box Method (KBM)

In the present study, two-phase nanofluid flow in a three-dimensional system is modeled over a stretching infinite solar plate and the heat transfer analysis is performed for this problem. The governing equations are presented based on previous studies and the suitable solution method is recommended due to infinite boundary condition in the problem. Keller Box Method (KBM) using the Maple 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2019

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927619001156